Spectrum Analyzer (Spectroradiometer)
Goniophotometer (light distribution curve tester)
LED flicker characteristic tester
Architectural lighting inspection
UV radiation detector
LED life and aging tester
Drive power and electronic ballast tester
Illuminance meter/Luminance meter/Photometer
Digital electrical parameter measuring instrument
Precision test power supply (AC/DC)
Electromagnetic compatibility (EMC) test system
Environmental safety testing equipment
Supporting test equipment
GPM-1800C測(cè)試系統(tǒng)主要由分布光度計(jì)、恒溫光度探頭、色度探測(cè)器、光譜儀、光導(dǎo)軌、標(biāo)準(zhǔn)燈、角度控制儀器、電源及電量測(cè)量?jī)x器等組成,合理選擇各類(lèi)測(cè)量?jī)x器將直接關(guān)系到測(cè)試系統(tǒng)的總體性能、精度、效率和成本。系統(tǒng)測(cè)量數(shù)據(jù)符合國(guó)際、國(guó)內(nèi)標(biāo)準(zhǔn)要求,IESNA文件格式輸出,可由其它照明和燈具設(shè)計(jì)軟件直接調(diào)用,采用貴金屬光纖點(diǎn)刷技術(shù)的高級(jí)換向器,實(shí)現(xiàn)不間斷連續(xù)測(cè)量,不會(huì)繞線(xiàn),智能啟動(dòng)和停止,轉(zhuǎn)動(dòng)平穩(wěn),低噪聲。
> 光度測(cè)量范圍:照度0.01lx - 99999lx
> 光度測(cè)量精度:1%(不包括標(biāo)準(zhǔn)光源本身不確定度)
> 光度線(xiàn)性:0.2%
> 恒溫光度探頭選用標(biāo)準(zhǔn)級(jí),內(nèi)部恒溫控制精度:±0.1°
> 雜散光:小于0.1%
> 角度精度:0.1度
> 傳動(dòng)角度分辨率:A角為0.01° α角為0.01°
>被測(cè)對(duì)象(含燈具和夾具)的最大質(zhì)量、尺寸
GPM-1800C :30kg 長(zhǎng):600mm(被測(cè)燈安裝基座尺寸) 高:390mm(被測(cè)燈安裝基座至光源中心尺寸)
> 測(cè)光距離: 最大30m

在測(cè)試過(guò)程中,探頭靜止不動(dòng),光源繞垂直軸(A 平面軸)和水平軸(α軸)轉(zhuǎn)動(dòng),從而得到光源的空間光強(qiáng)分布。

GPM-1800C分布式光度計(jì)測(cè)試系統(tǒng)滿(mǎn)足以下標(biāo)準(zhǔn)中關(guān)于光度學(xué)、色度學(xué)和電學(xué)參數(shù)的測(cè)試要求
1) NAVGUIDE “Aids to Navigation Manual 2010 Edition”
2) GB 12708-91 《航標(biāo)燈光信號(hào)顏色》
3) JT/T 761-2009 《航標(biāo)燈通用技術(shù)條件》
4) JT/T 730-2008 《航標(biāo)燈光強(qiáng)測(cè)量和燈光射程計(jì)算》